Carefully insert the system air duct (1).
Ensure that the cables on the left and right side walls do not interfere with
the system air duct.
Use the green touch points (A) to hold the system air duct.
▶
Push down the system air duct into the chassis until the locking tab snaps
into place.
4.5.3
Rack model
4.5.3.1
Installing the rack front cover
Figure 20: Installing the rack front cover (A)
▶
Fit the rack front cover on the server front.
▶
Ensure that the rack mounting brackets properly engage on both sides of
the chassis as shown in the close-up.
Basic hardware procedures
TX2550 M5
Upgrade and Maintenance Manual
69