Click
Start Fan Test
.
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
▶
Open the ServerView Operations Manager and log in.
▶
Under
Administration
select
Server Configuration
.
▶
In the hierarchy tree of the
Server list
tab, select the server to be
configured.
▶
In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking
GO...
. In the left-hand section of
the window, the
Configuration
tab is being activated.
▶
In the navigation area of the
Configuration
tab, select
Other Settings
.
▶
Under
Daily Fan Test
, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
▶
Click
Save Page
.
The fan test will be started at the specified time.
▶
After the fan test is complete, restore the time setting to its initial value and
click
Save Page
.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
Please follow the instructions provided separately.
5.3.21
Specifying the chassis model
In order to have your server displayed correctly as a rack system in the
ServerView management user interface after a chassis conversion, the chassis
model setting needs to be updated.
This can be accomplished using the ServerView Installation Manager or
Maintenance Tools:
Basic software procedures
TX2550 M5
Upgrade and Maintenance Manual
141
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...