8.4
Replacing a fan module (low performance
variant)
If a fan module of the low performance variant is defective, replace the
whole fan bridge, see
"Replacing the fan bridge (low performance
.
It is not possible to replace a fan module.
8.5
Replacing the fan bridge (high
performance variant)
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
tool-less
Preliminary steps
▶
"Locating the defective server" on page 47
▶
"Shutting down the server" on page 49
.
▶
"Disconnecting the power cord" on page 50
.
▶
"Getting access to the component" on page 51
Removing the defective fan bridge
▶
"Removing the fan bridge with fan modules
(high performance variant)" on page 92
▶
Remove all fan modules from the fan bridge, see
system fan module" on page 317
Fans
TX2550 M5
Upgrade and Maintenance Manual
319