18.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with CPU heat
sink
installed in CPU slot CPU 1
1 memory module
installed in DIMM slot 1A
Front panel module
without connected USB3.0
1 PSU
installed in PSU bay PSU 1
Table 5: Minimum startup configuration - components
Cable
Notes
Front panel cable
connected to the system board
Power cable
Table 6: Minimum startup configuration - cables
▶
"Shutting down the server" on page 49
.
▶
"Disconnecting the power cord" on page 50
.
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 82
▶
Connect a display to the server.
▶
Switch on the server, see
"Switching on the server" on page 83
Appendix A
TX2550 M5
Upgrade and Maintenance Manual
587
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...