# of
Beep
Description
Action
1
Invalid password
▶
Check for the correct password and try
again. Make sure that the caps lock key
is deactivated.
5
No Console Input
devices
1
or Output
devices
2
are found
Booting will continue.
1
Serial console redirection is considered
a console output device if enabled.
2
Serial console redirection is considered
a console input device if enabled.
This beep code is only an information.
6
Flash update is failed
A processing bar and an error message is
displayed on the screen.
This beep code is only an information.
8
Platform PCI resource
requirements cannot be
met
▶
Check the connection of your
expansion card whether it is installed in
a correct slot.
▶
Enter the BIOS setup menu.
▶
Open the
Advanced
menu.
▶
Check in the
PCI Subsystem Settings
the parameter
Above 4G Decoding
.
This parameter must be set to
Enabled
.
Appendix A
514
Upgrade and Maintenance Manual
TX1330 M4
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...