When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed
.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Save & Exit
menu.
●
Select
Save Changes and Exit
or
Save Changes and Reset
.
●
Verify that the Global Error indicator stops flashing.
▶
"Verifying the system time settings" on page 116
▶
"Updating or recovering the BIOS and iRMC S5" on page 103
▶
If applicable, activate TPM functionality in the system BIOS under
Security
>
TPM (Security Chip) Setting
>
Security Chip
. For more information, see
the corresponding BIOS Setup Utility reference manual.
▶
"Verifying system information backup or restore" on page 105
.
▶
"Looking for MAC/WWN/GUID and SAS addresses" on page 123
▶
"Updating the NIC configuration file in a Linux and VMware environment" on
page 120
.
▶
"Resuming BitLocker functionality" on page 121
▶
If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced controller (expansion
card or onboard).
Configuration of network settings should be performed by the
customer. For more information, see
.
▶
If applicable, restore LAN teaming configurations, see
.
System board and components
458
Upgrade and Maintenance Manual
TX1330 M4
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...