Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
▶
Log in as root.
▶
Enter the command below, followed by [ENTER]:
<CPU#>
parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
▶
Log in as root.
▶
Enter the commands below, followed by [ENTER]:
1.
/etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2.
cd /etc/srvmagt
3.
rm -f cehist.bin
4.
/etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
▶
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Basic software procedures
TX1330 M4
Upgrade and Maintenance Manual
113
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...