Tools:
tool-less
CAUTION
▶
When replacing a PSU in a non-redundant PSU configuration, the
server must be switched off first.
▶
Replace the PSU after specifying the one that breaks down at work
by revitalization.
Note for servers using CMA (Cable Management Arm)
Regarding of removing PSUs, additional tasks are needed, due to an
interference between CMA and the PSUs.
▶
If applicable, open the CMA of the server below to get enough space at the
under side of your server.
▶
Unlock the CMA stopper of the server below.
▶
Pull out the CMA of the server below to the rear side.
▶
Push the lock spring inward to unlock the CMA bracket, see
.
▶
Remove the CMA.
▶
Hold the CMA including cables in the one hand.
▶
Remove the PSU (see
) and install the new PSU carefully.
▶
Mount the complete assembly (CMA bracket and the CMA) again into the
rail.
▶
If applicable, close the CMA of the server below.
Preliminary steps
▶
"Locating the defective server" on page 45
▶
Check which PSU is defective.
PSU is defective when the PSU status indicator lights orange. For more
information, see
"Indicator on hot-plug PSU" on page 511
▶
Only when replacing a PSU in a non-redundant configuration:
Power supply unit (PSU)
TX1330 M4
Upgrade and Maintenance Manual
153
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...