Status
Description
green on
The battery unit is fully charged.
flashing orange
A battery unit failure has been detected.
Possible causes:
– Capacity failure
– Overheating
orange on
A general battery failure has occurred.
17.2.4
Acoustic indicators
PEI Beep Codes
Pre-EFI Initialization (PEI) - memory Initialization (bootblock)
# of
Beep
Description
Action
1
Memory not installed
▶
Check if the memory module is
installed.
▶
Check if the memory module is
installed correctly.
2
Recovery started
Recovery procedure is initialized by
jumper settings on the system board and
announced with two beep.
This is only an information.
4
Recovery failed
▶
Restart the recovery procedure again.
▶
If the same beep code sounds again,
replace the system board.
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
Appendix A
TX1330 M4
Upgrade and Maintenance Manual
513
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...