Ensure that the controllers have been assigned as primary or secondary
according to your requirements.
For more information, see the relevant LAN driver manual.
After replacing a system board
The following procedure must be done for each system board that is
replaced.
▶
Confirm with the customer whether the onboard LAN controller you have
replaced has been used as part of a LAN teaming configuration.
▶
If LAN teaming has been active, you will need to restore the configuration
using the LAN driver utility or OS teaming software.
For more information, see the relevant LAN driver manual.
5.3.19
Switching off the ID indicator
▶
Press the ID button on the front panel, or use the ServerView Operations
Manager, the iRMC S5 web interface or the Infrastructure Manager to switch
off the ID indicator after the maintenance task has been concluded
successfully.
For more information, see
"Locating the defective server" on page 45
or
the "ServerView Suite Local Service Concept (LSC)", the iRMC user
guides or the Infrastructure Manager documentation.
Using the ID button on the front panel
▶
Press the ID button on the front panel to switch off the ID indicators.
Basic software procedures
TX1330 M4
Upgrade and Maintenance Manual
129
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...