Installing the new FJBU
▶
"Installing an FJBU" on page 160
.
Concluding steps
▶
No steps needed.
6.6
Converting a standard power supply to a
redundant power supply
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
The standard power supply can be replaced by a redundant power supply. The
redundant power supply consists of up to two PSUs. The upgrade kit contains
only one PSU, for PSU redundancy the second PSU must be additionally
ordered.
The upgrade kit for the redundant power supply consists of the following parts:
–
PSU cage with power distribution board
–
two power cables
–
one hot-plug PSU
–
dummy cover (if only one PSU is installed, you have to install the dummy
cover in the second bay)
–
several screws
–
one redundant system fan
If you install a redundant power supply, a redundant system fan is
necessary.
Power supply unit (PSU)
164
Upgrade and Maintenance Manual
TX1330 M4
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...