Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
Using ServerView Maintenance Tools (Windows only)
▶
Launch the ServerView Maintenance Tools:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
▶
Choose the
Memory
status tab.
▶
Select the memory module which shows the pre-failure status.
▶
Click on
Reset Status
.
The
Reset Status
button will only be available if the selected memory
module contains errors.
▶
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using the command line interface (Linux/VMware only)
The memory error counter can be reset using the
meclear
utility which is part
of the ServerView agents for Linux.
meclear
(Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it has
been replaced.
For more Information, see the
meclear
manual pages.
▶
Log in as root.
▶
Enter the command below, followed by [ENTER]:
/usr/sbin/meclear
▶
Select the number of a memory module with a status other than
OK
or
Not
available
.
▶
Repeat the step above until all memory modules show the
OK
status.
Basic software procedures
TX1330 M4
Upgrade and Maintenance Manual
111
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...