Remove the system fan module, see
"Removing the system fan module" on
.
▶
If applicable, remove the SAS expander board holder without disconnecting
cables, see
"Removing the SAS expander board holder" on page 273
Position the SAS expander board holder on the HDD cages to get more
space.
▶
If applicable,
"Removing an expansion card" on page 305
Installing the M.2 SSD
CAUTION
An M.2 SSD in M.2 slot 2 is not recognized, if M.2 slot 1 is free.
▶
The M.2 slot 1 must be equipped first.
Each M.2 SSD needs one hexagon stand-off for fastening. To support
different length of M.2 SSD, several nuts are on the system board
indicating the positions for fastening the M.2 SSD.
If no M.2 SSD has been installed before:
▶
Remove the screw (see orange circles in
).
If the hexagon stand-off is unscrewed as well, remove the screw from
the hexagon stand-off.
▶
Install the hexagon stand-off on the right position depending on the length of
the M.2 SSD.
System board and components
434
Upgrade and Maintenance Manual
TX1330 M4
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...