Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
▶
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
▶
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
▶
Insert a new CMOS battery of the same type into the socket (3) and (4).
Concluding steps
▶
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
▶
If applicable, install the SAS expander board holder, see
expander board holder " on page 271
.
▶
Install the system fan module, see
"Installing the system fan module" on
.
▶
.
▶
"Connecting the power cord" on page 79
.
▶
"Switching on the server" on page 81
.
▶
BIOS settings are automatically reloaded. Time and date must be set
manually, see
"Verifying the system time settings" on page 116
.
You must manually change the BIOS settings according to the note
on your current BIOS settings, see
"Note on BIOS settings recovery"
System board and components
416
Upgrade and Maintenance Manual
TX1330 M4
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...