Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
the current number of remaining boot attempts
is displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
▶
Exit the BIOS.
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
Please note, if the customer does not know about the original boot retry
values:
If the system boots up and no further errors occur within 6 hours after
that successful boot attempt, the boot retry counter will automatically be
reset to its default value. Please take into account, that the specified
number of boot attempts can only be determined after this period of
time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Resetting the boot retry counter in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
press the [+] or [-] keys to specify the maximum
number of boot attempts (0 to 7).
▶
Exit the BIOS.
Basic software procedures
TX1330 M4
Upgrade and Maintenance Manual
109
Summary of Contents for PRIMERGY TX1330 M4
Page 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Page 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Page 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Page 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Page 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Page 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Page 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Page 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Page 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Page 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...