RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all data are lost!
RAID 1
RAID 5
RAID 6
RAID 10
Removing an HDD module from a RAID 1 array will not result in
data loss. However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger capacity.
After replacing the HDD module, RAID rebuild will be
performed as a background process, see
a RAID array rebuild" on page 69
.
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using HII
Configuration Utility.
CAUTION
All data on all HDDs in the array will be lost when deleting the RAID
array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see RAID documentation in
.
Hard disk drives (HDD)
TX1310 M5
Upgrade and Maintenance Manual
93
Summary of Contents for PRIMERGY TX1310 M5
Page 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Page 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Page 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Page 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Page 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Page 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Page 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Page 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...