Replacing the defective CMOS battery
1
2
3
4
Figure 120: Replacing the CMOS battery
▶
Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
▶
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
▶
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
▶
Insert a new CMOS battery of the same type into the socket (3) and (4).
Concluding steps
▶
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
▶
▶
"Connecting the power cord" on page 56
▶
"Switching on the server" on page 57
▶
"Installing the bay cover" on page 58
▶
"Locking the server" on page 59