Enabling the TPM in the system board BIOS
Proceed as follows:
▶
Switch on or restart your server.
▶
As soon as the startup screen appears, press the [F2] function key to enter
the BIOS setup menu.
▶
Select the
Advanced
menu.
▶
Select the
Trusted Computing
submenu.
▶
Set the
TPM Support
setting to
Enabled
.
▶
Under
Pending TPM operation
, select the desired TPM operation mode.
▶
Save your changes and exit the BIOS.
For information on how to access the BIOS and modify settings, see the
corresponding BIOS Setup Utility reference manual.
15.4.3 Removing the TPM
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Removing the TPM:
– Bit screw driver
– Flat nose pliers
– TPM bit insert
(*)
(*)
For Japan:
– TPM module fixing tool (S26361-F3552-L909)
System board and components
188
Upgrade and Maintenance Manual
TX1310 M5