"Switching on the server" on page 57
.
When the system is powered on after a CPU has been replaced or
upgraded, the message "CPU has been changed" appears.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
To delete this message:
1
.
Restart the system and wait for screen output to appear.
2
.
Press the [F2] to enter the BIOS.
3
.
If assigned, enter the BIOS password and press [Enter].
4
.
Select the
Save & Exit
menu.
5
.
Select
Save Changes and Exit
or
Save Changes and Reset
.
▶
"Installing the bay cover" on page 58
▶
"Locking the server" on page 59
▶
"Updating or recovering the BIOS" on page 63
.
▶
Restore the BIOS settings manually.
▶
It is necessary to set
Advanced
-
Trusted Computing
-
TPM support
setting to
Enabled
in order to activate the TPM functionality in the system
BIOS. For more information, refer to the corresponding BIOS Setup Utility
reference manual.
▶
"Verifying the system time settings" on page 65
▶
"Looking up for MAC/WWN addresses" on page 70
▶
"Updating the NIC configuration file in a Linux/VMware OS" on page 67
▶
If applicable,
"Resuming BitLocker functionality" on page 68
▶
If applicable, reconfigure your network settings in the operating system
according to the original configuration of the replaced controller (expansion
card or onboard).
Configuration of network settings should be performed by the
customer. For more information, see
.
▶
"Using the Chassis ID Prom Tool" on page 71
.
System board and components
214
Upgrade and Maintenance Manual
TX1310 M5
Summary of Contents for PRIMERGY TX1310 M5
Page 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Page 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Page 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Page 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Page 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Page 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Page 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Page 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...