Disconnect all storage devices from the server beside the M.2 SSD.
▶
Power on the server. Once the server has been started, then enter the BIOS
setup menu and select the DVD drive as primary boot device.
▶
Insert the CD into the DVD drive and reboot the server. The server will boot
from the installer CD.
▶
Follow the on-screen instructions to install the ESXi. When the installation is
complete, you will be asked to reboot the server.
▶
While the server is rebooting, enter the BIOS setup menu again and select
the M.2 SSD as primary boot device.
The installation of the ESXi to the M.2 SSD is complete.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
The M.2 SSD can be used only for boot device. Do not use VMFS on
the M.2 SSD because of not meeting required endurance. For more
information, see the VMware Knowledge Base 2145210.
https://kb.vmware.com/s/article/2145210
For Japan
In order to setup the ESXi, see the corresponding version of the
"VMware vSphere Software Description" from the following URL and
reinstall ESXi to the M.2 SSD.
https://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/
15.5.3 Removing an M.2 SSD
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
tool-less
System board and components
TX1310 M5
Upgrade and Maintenance Manual
201
Summary of Contents for PRIMERGY TX1310 M5
Page 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Page 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Page 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Page 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Page 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Page 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Page 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Page 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...