98
Upgrade and Maintenance Manual
RX2530
M1
Basic software procedures
Ê
Note down the new 16-digit WWN address found under
Adapter Port Name
.
Ê
Press
[Esc]
to return to the main menu and exit the QLogic BIOS utility.
Ê
Inform the customer about the changed WWN address.
5.2.17 Using the Chassis ID Prom Tool
The Chassis ID EPROM located on a dedicated Chassis ID board or on your
server’s front panel board contains system information like server name and
model, housing type, serial number and manufacturing data.
In order to integrate your system into the ServerView management environment
and to enable server installation using the ServerView Installation Manager,
system data needs to be complete and correct.
After replacing the Chassis ID EPROM, system information has to be entered
using the Chassis ID Prom tool. The tool and further instructions are available
to maintenance personnel from the Fujitsu Technology Solutions Extranet:
https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/
Ê
Select your PRIMERGY system from the main area of the page.
Ê
From the categories selection, choose
Software & Tools Documentation
.
Ê
In the
Tools
area click
Tools: Chassis-IDProm Tool
to download the file
(
tool-chassis-Idprom-Tool.zip
).
I
For the Japanese market, follow the instructions provided separately.
Note on Cool-safe
®
Advanced Thermal Design (ATD)
I
If the Cool-safe
®
Advanced Thermal Design (ATD) option is available
and has been enabled for your server, please set information within the
Chassis ID Prom Tool accordingly.
V
CAUTION!
Please note that you can only set the ATD flag. Resetting the ATD flag
using the Chassis ID Prom Tool is not possible!
The ATD option can only be ordered from the manufacturer
as a factory preset. To find out if your server is ATD-enabled,
check for the ATD logo on the identification rating plate.
For further information on Cool-safe
®
Advanced Thermal
Design (ATD), please refer to your server’s operating manual.
Summary of Contents for PRIMERGY RX2530 M1
Page 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Page 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Page 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Page 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Page 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Page 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Page 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Page 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...