126
Upgrade and Maintenance Manual
RX2530
M1
Hard disk drives / solid state drives
7.2.6
Removing 2.5-inch HDD/SSD modules
7.2.6.1
Preliminary steps
Ê
If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
"Performing a RAID array
rebuild" on page 96
.
Summary of Contents for PRIMERGY RX2530 M1
Page 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Page 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Page 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Page 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Page 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Page 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Page 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Page 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...