RX2530 M1
Upgrade and Maintenance Manual
245
Processors
Figure 166: Removing the load plate
Ê
Make sure that the load plate is in the fully open position.
Ê
Remove the socket cover and save it for future use (1).
Ê
Unlatch the socket release lever 1 by pushing it down and inward (2).
Ê
Fold back the socket release lever 1 (3).
Installing the processor
V
CAUTION when replacing a system board
Ê
Use a magnifying glass (recommended) to inspect the socket spring
contacts for damages from different angles. Do not use the spare
system board if any irregularities are visible. Possible damages:
– Contact spring is bent backwards upon itself
– Contact spring tip position is shifted or out of alignment
Never try to fix bent contact springs. Doing so may result in loss of
electrical performance and reliability.