250
Upgrade and Maintenance Manual
RX2530
M1
Processors
11.2.5 Installing four additional fan modules
Figure 172: Removing sponges
Ê
Remove the four sponges from the bays 5, 6, 7and 8.
Ê
Install four fan modules in bays 5, 6, 7and 8 as described in section
"Installing the new fan module" on page 159
(overview of installed fans in all
bays see figure
82
).
11.2.6 Concluding steps
Ê
"Installing the CPU air guides" on page 69
Ê
"Reassembling" on page 54
Ê
"Connecting the server to the mains" on page 60
I
If Global Error LED is flashing with error message
CPU has been
changed
on display after the system is powered on, please follow the
procedure below.
Ê
Restart your server.
Ê
As soon as the startup screen appears, press the
[F2]
function key to
enter the BIOS.
If a password is assigned, enter the password and press
[Enter]
.
Ê
Select the
Save & Exit
menu.
Ê
Select
Save Changes and Exit
or
Save Changes and Reset
.
Ê
Verify that the LED stops flashing.
Summary of Contents for PRIMERGY RX2530 M1
Page 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Page 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Page 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Page 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Page 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Page 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Page 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Page 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...