RX2530 M1
Upgrade and Maintenance Manual
257
Processors
Figure 178: Applying the thermal paste
Ê
Apply a small point-shaped amount of thermal paste (1.0 gram, see
description above) to the center of the processor surface as shown.
V
CAUTION!
Do not mix different types of thermal paste.
11.3.6 Installing the heat sink
I
Processors with 135 W and more need dedicated heat sinks (part
number V26898-B1000-V2, see figure
170
).
Figure 179: Installing the heat sink
Ê
Align the heat sink and fit it on the processor socket.
Ê
Position the screws in the holes carefully, making sure they are upright.
Ê
Fasten it in a crossover pattern with four screws according to the numbering
(torque 6.0 Nm, the description of this torque value doesn't apply to the
Japanese market).