RX2530 M1
Upgrade and Maintenance Manual
139
Hard disk drives / solid state drives
7.2.9.3
Removing the defective 10 x 2.5-inch HDD backplane
Figure 64: Removing the 10 x 2.5-inch HDD backplane
Ê
Pull the HDD backplane upward until the six hooks disengage (see circles).
Ê
Take out the HDD backplane.
7.2.9.4
Installing the new 10 x 2.5-inch HDD backplane
Figure 65: Installing the 10 x 2.5-inch HDD backplane
Ê
Position the HDD backplane on the six hooks (see circles).
Ê
Push the HDD backplane downward. Make sure that the lower cant of the
HDD backplane fits in the guides (A).