RX2530 M1
Upgrade and Maintenance Manual
35
Important information
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
●
Route the cables in such a way that they do not create a potential hazard
(make sure no-one can trip over them) and that they cannot be damaged.
When connecting the server, refer to the relevant instructions in this manual.
●
Never connect or disconnect data transmission lines during a storm (risk of
lightning hazard).
●
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get
inside the server (risk of electric shock, short circuit).
●
In emergencies (e.g. damaged casing, controls or cables, penetration of
liquids or foreign bodies), contact the system administrator or your customer
service team. Only disconnect the system from the mains power supply if
there is no risk of harming yourself.
●
Proper operation of the system (in accordance with IEC 60950-1 resp.
EN 60950-1) is only ensured if the casing is completely assembled and the
rear covers for the installation slots have been fitted (electric shock, cooling,
fire protection, interference suppression).
●
Only install system expansions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and those relating to
telecommunication terminals. If you install other expansions, they may
damage the system or violate the safety regulations. Information on which
system expansions are approved for installation can be obtained from our
customer service center or your sales outlet.
●
The components marked with a warning notice (e.g. lightning symbol) may
only be opened, removed or exchanged by authorized, qualified personnel.
Exception: CSS components can be replaced.
●
The warranty is void if the server is damaged during installation or
replacement of system expansions.
●
Only set screen resolutions and refresh rates that are specified in the
operating manual for the monitor. Otherwise, you may damage your monitor.
If you are in any doubt, contact your sales outlet or customer service center.
●
Before installing/removing internal options to/from the server, turn off the
server, all peripheral devices, and any other connected devices. Also unplug
all power cords from the outlet. Failure to do so can cause electric shock.
Summary of Contents for PRIMERGY RX2530 M1
Page 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Page 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Page 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Page 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Page 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Page 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Page 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Page 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...