226
Upgrade and Maintenance Manual
RX2530
M1
Main memory
10.1.1 Population rules
– Populate memory slot 1 / channel A (DIMM 1A) first.
– In case of dual processor configurations, populate memory slot
1 / channel D (DIMM 1D) second.
– Within all channels, memory slot 1 must be populated prior to slot 2.
(for all CPUs).
– If memory modules with different ranks are used, always populate the higher
number rank DIMM first (starting from slot 1).
– If memory modules with different capacities are used:
– Populate modules with higher capacities first.
– Within a channel, populate modules in descending order of capacity.
– If memory modules with different speeds are used, the lowest clock rate
applies for all DIMMs. Regardless of the mode, all DIMMs will run at the
highest common frequency that is allowed by the SPD Data of the DIMMs
and the maximum speed of the selected configuration.
– RDIMMs and LRDIMMs are allowed.
– Only ECC DIMMs are allowed.
– Mixing of quad-rank DIMMs in one channel and three DIMMs in another
channel (3DPC) on the same CPU is not allowed.
Summary of Contents for PRIMERGY RX2530 M1
Page 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Page 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Page 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Page 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Page 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Page 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Page 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Page 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...