Installing the new 2.5-inch HDD module
▶
Install the HDD/SSD module, see
"Installing 2.5-inch HDD/SSD modules"
.
Concluding steps
▶
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see
7.3.5
Replacing the HDD backplane
Field Replaceable Unit
(FRU)
Hardware: 20 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 37
▶
"Shutting down the server" on page 37
.
▶
"Disconnecting the power cord" on page 38
.
▶
"Getting access to the component" on page 39
▶
Remove all HDD/SSD modules, see
.
CAUTION
The HDD/SSD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
Hard disk drive (HDD) / solid state disk (SSD)
RX2450 M1
Upgrade and Maintenance Manual
95