Installing the new system board
▶
Check the settings on the new system board, see
.
▶
Insert the system board by holding it at a slight angle.
▶
Lower the system board carefully into the chassis.
▶
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion.
▶
Fasten the system board with the nine screws, see
.
▶
Install the two stand-offs, see
.
▶
"Installing the air duct" on page 63
.
▶
Remove the heat sink with the CPU from the defective system board, see
"Removing the heat sink" on page 170
.
▶
Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
Returned system boards without this cover probably have to be
scrapped.
▶
Install the heat sink with the CPU on the new system board, see
.
▶
Connect all cables to the system board.
.
Concluding steps
▶
"Installing the new fan module" on page 102
.
▶
Install all memory modules, see
"Installing memory modules" on page 160
.
Ensure that you reinstall each memory module in the slot it was
located before the replacement.
▶
Install the AOC card and the corresponding riser card, see
▶
"Installing the air duct" on page 63
.
System board and components
RX2450 M1
Upgrade and Maintenance Manual
197
Summary of Contents for PRIMERGY RX2450 M1
Page 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Page 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Page 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Page 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Page 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Page 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...
Page 222: ......