Concluding steps
▶
▶
"Connecting the power cord" on page 48
▶
"Switching on the server" on page 49
9.4.2
Removing a GPU card from riser module 1
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
– Phillips PH1 / (+) No. 1 screw driver
– Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Shutting down the server" on page 37
.
▶
"Disconnecting the power cord" on page 38
.
▶
"Getting access to the component" on page 39
▶
"Removing the air ducts" on page 62
.
▶
Remove the riser module 1, see
"Removing the riser module 1" on page 51
Removing the GPU card from riser module 1
The GPU card can only be installed in slot 3 for riser module 1.
▶
Disconnect the power cable from the GPU card and the system board.
Expansion cards and riser cards
RX2450 M1
Upgrade and Maintenance Manual
129