"Shutting down the server" on page 37
.
▶
"Disconnecting the power cord (AC PSU)" on page 38
▶
"Getting access to the component" on page 39
Replacing the defective CMOS battery
1
2
3
4
Figure 156: Replacing the CMOS battery
▶
Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
▶
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
▶
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
▶
Insert a new CMOS battery of the same type into the socket (3) and (4).
Concluding steps
▶
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
▶
▶
"Connecting the power cord" on page 48
System board and components
RX2450 M1
Upgrade and Maintenance Manual
193