4.9.3
Installing the air duct
Installing CPU air ducts
Figure 36: Preparing air duct
▶
Place the air duct on CPU 1 between P1-DIMM A1 and heat sink, P1-
DIMM E1 and heat sink.
▶
Place the air duct on CPU 2 between P2-DIMM A1 and heat sink, P2-
DIMM E1 and heat sink.
Figure 37: Installing air duct
▶
Insert each CPU air duct in the groove between the fan cages.
Basic hardware procedures
RX2450 M1
Upgrade and Maintenance Manual
63