![background image](http://html.mh-extra.com/html/fujitsu/primergy-rx2450-m1/primergy-rx2450-m1_upgrade-and-maintenance-manual_121113208.webp)
14.2.2.2
Indicators on hot-plug HDD / SSD / PCIe SSD modules
Figure 165: Indicators on an HDD / SSD / PCIe SSD module
1
Activity indicator
2
Status indicator
Activity indicator (1)
Status
Description
blue on
SATA drive is being accessed.
flashing blue
SAS drive or NVMe drive is installed.
Status indicator (2)
Status
Description
off
non-RAID configuration
red on
Failure of drive with Rapid Storage Technology enterprise
(RSTe) support
flashing red at
1 Hz
Rebuild drive with RSTe support
flashing red with
two blinks and
one stop at 1 Hz
Hot spare for drive with RSTe support
red on for five
seconds, then off
Power-on for drive with RSTe support
flashing red at
4 Hz
Identification of drive with RSTe support
Appendix A
208
Upgrade and Maintenance Manual
RX2450 M1
Summary of Contents for PRIMERGY RX2450 M1
Page 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Page 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Page 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Page 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Page 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Page 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...