![background image](http://html.mh-extra.com/html/fujitsu/primergy-rx2450-m1/primergy-rx2450-m1_upgrade-and-maintenance-manual_121113091.webp)
Concluding steps
No steps needed.
7.3.3
Removing 2.5-inch HDD/SSD modules
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
tool-less
Preliminary steps
▶
If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
RAID 1
RAID 5
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see
RAID array rebuild" on page 72
.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
Hard disk drive (HDD) / solid state disk (SSD)
RX2450 M1
Upgrade and Maintenance Manual
91
Summary of Contents for PRIMERGY RX2450 M1
Page 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Page 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Page 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Page 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Page 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Page 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...
Page 222: ......