Connect four cables to the connectors "SAS#1", "SAS#2", "SAS#3" and
"SAS#4" on the HDD backplane and to the connectors "C0", "C1", "C2" and
"C3" on the first RAID controller.
▶
Connect one cable to the connectors "SAS#5" on the HDD backplane and to
the connector "C0" on the second RAID controller.
▶
Fasten the cables with three cable ties (see blue circles).
▶
Fasten the cables with the cable holder (see orange circle).
9.4
GPU cards in riser modules
9.4.1
Installing a GPU card in riser module 1
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
– Phillips PH1 / (+) No. 1 screw driver
– Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Shutting down the server" on page 37
.
▶
"Disconnecting the power cord" on page 38
.
▶
"Getting access to the component" on page 39
▶
Remove the riser module 1, see
"Removing the riser module 1" on page 51
Installing the GPU card in riser module 1
The GPU card can only be installed in slot 3 for riser module 1.
Expansion cards and riser cards
RX2450 M1
Upgrade and Maintenance Manual
125
Summary of Contents for PRIMERGY RX2450 M1
Page 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Page 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Page 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Page 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Page 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Page 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...
Page 222: ......