Loosen the captive screws (see circles) following the sequence described
below and using a Star screw driver (T20):
CAUTION
▶
Please do not use an electric screwdriver.
There is a possibility the washer on the heat sink mounting screw
may be damaged. Ensure to follow the removing procedure as below.
▶
Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
▶
Loosen the captive screws 4 and then 3 rotating them two or three turns
each.
▶
Repeat the step 2 until the screws 4 and 3 are completely loosened.
▶
Repeat the step 4 until the screws 2 and 1 are completely loosened.
▶
Lift the heat sink out of the chassis.
CAUTION
▶
Pay special attention not to damage any system board
components surrounding the CPU socket.
Processor (CPU)
RX2450 M1
Upgrade and Maintenance Manual
171