U41840-J-Z125-7-76
81
Installing the Rack
I
It is recommended to install the ETERNUS CS800 S5 system in a controlled or
restricted area to prevent access by untrained personnel. In addition, it is
recommended that system installation is performed only by qualified IT personnel.
Rack Requirements
and
contain the rack requirements for the ETERNUS CS800 S5 compo-
nents.
Table 18: Rack Requirements - for Entry
Table 19: Rack Requirements - for Scale
The rack systems from Fujitsu (PRIMECENTER Rack) support the installation of
ETERNUS CS800 S5 components. Installation in most current rack systems from other
manufacturers is also supported.
To ensure proper ventilation, any unused areas in the rack must be sealed using dummy
covers. Ventilation takes place from the front to the back and may not be obstructed!
The power is supplied via the multiple socket outlets fitted in the rack.
ETERNUS CS800 S5 - Entry
With JX40 storage modules
Height
2 HU, i.e. 8.9 cm,
4 HU, i.e. 17.8 cm
Width (side to side)
48.26 cm
48.26 cm
Depth (front to back)
77 cm
77 cm
Weight (stand alone)
25 kg
60 kg
Ventilation Clearance At least 200 mm on the front and rear
ETERNUS CS800 S5 - Scale
With DX80 S2 expansion modules
Height
4 HU, i.e. 17.8 cm
Up to 22 HU, i.e. 97.8 cm (9 expansions)
Width (side to side)
48.26 cm
48.26 cm
Depth (front to back)
77 cm
77 cm
Weight (stand alone)
60 kg
Up to 375 kg
Ventilation Clearance At least 200 mm on the front and rear
Summary of Contents for ETERNUS CS800 S5
Page 1: ...Edition June 2014 English ETERNUS CS800 S5 V2 3 1 User Guide ...
Page 14: ...Contents U41840 J Z125 7 76 ...
Page 30: ...Environmental Protection Important Information 28 U41840 J Z125 7 76 ...
Page 48: ...Network Configuration System Description 46 U41840 J Z125 7 76 ...
Page 80: ...Locating the Serial Number Hardware Description and Basic Operations 78 U41840 J Z125 7 76 ...
Page 116: ...Further Configurations Installing the ETERNUS CS800 S5 Modules 102 U41840 J Z125 7 76 ...
Page 150: ...The Remote Management Console Remote Management 136 U41840 J Z125 7 76 ...
Page 190: ...AIS Connect Configuration Wizards 176 U41840 J Z125 7 76 ...
Page 200: ...Current Activity Overview Home Page 186 U41840 J Z125 7 76 ...
Page 301: ...Configuration System U41840 J Z125 7 76 287 Figure 177 Network Configuration ...
Page 353: ...Configuration Contacts U41840 J Z125 7 76 339 Figure 211 Primary and Secondary Pages ...
Page 402: ...Reports Replication 388 U41840 J Z125 7 76 ...
Page 406: ...Hardware Status 392 U41840 J Z125 7 76 Figure 236 System Board Page ...
Page 432: ...Activity Log Status 418 U41840 J Z125 7 76 ...
Page 442: ...Service Tickets Alerts 428 U41840 J Z125 7 76 ...
Page 462: ...Reboot Shutdown Utilities 448 U41840 J Z125 7 76 ...
Page 470: ...Common Problems and Solutions Troubleshooting 456 U41840 J Z125 7 76 ...
Page 496: ...Additional Specifications for Scale Mode System Specifications S5 626 U41840 J Z125 7 76 ...
Page 634: ...Index 634 U41840 J Z125 7 76 ...