PTT
Configuration
276
U41840-J-Z125-7-76
Use the
FC Initiators & Targets
page to perform the following tasks:
●
View information about initiator and target Fibre Channel ports (see
ators and Targets List" on page 276
●
Change the mode of a Fibre Channel port (see
"Editing the Fibre Channel Port Type"
Fibre Channel Initiators and Targets List
The
Fibre Channel Initiators & Targets
section displays the following information for all
Fibre Channel ports:
●
Alias
- The alias of the Fibre Channel port.
●
WWPN
- The World Wide Port Number of the Fibre Channel Port.
●
Port Type
- The current mode of the Fibre Channel port (
Initiator
or
Target
).
I
Click
Refresh
to update the list with the latest port information.
The
Backpanel Locations
section displays a graphical representation of the Fibre
Channel ports as they appear on the rear of the system. The diagram shows the status of
each Fibre Channel port:
Mapped Target
(green),
Unmapped Target
(yellow),
Active
Initiator
(blue), or
Inactive Initiator
(orange).
Editing the Fibre Channel Port Type
Edit the port type to change the mode of a Fibre Channel port to initiator or target mode.
You can change the port mode only on inactive connections:
●
Before changing a Fibre Channel port type from initiator to target, unplug the Fibre
Channel port wire connection.
●
Before changing a Fibre Channel port type from target to initiator, un-map any host
mapping on the Fibre Channel port, and unplug the Fibre Channel port wire connection.
To edit the Fibre Channel Port type:
1. Select the port in the list and click
Edit
.
2. Select the new port mode (
Initiator
or
Target
) in the drop-down box (see
3. Click
Update
.
Summary of Contents for ETERNUS CS800 S5
Page 1: ...Edition June 2014 English ETERNUS CS800 S5 V2 3 1 User Guide ...
Page 14: ...Contents U41840 J Z125 7 76 ...
Page 30: ...Environmental Protection Important Information 28 U41840 J Z125 7 76 ...
Page 48: ...Network Configuration System Description 46 U41840 J Z125 7 76 ...
Page 80: ...Locating the Serial Number Hardware Description and Basic Operations 78 U41840 J Z125 7 76 ...
Page 116: ...Further Configurations Installing the ETERNUS CS800 S5 Modules 102 U41840 J Z125 7 76 ...
Page 150: ...The Remote Management Console Remote Management 136 U41840 J Z125 7 76 ...
Page 190: ...AIS Connect Configuration Wizards 176 U41840 J Z125 7 76 ...
Page 200: ...Current Activity Overview Home Page 186 U41840 J Z125 7 76 ...
Page 301: ...Configuration System U41840 J Z125 7 76 287 Figure 177 Network Configuration ...
Page 353: ...Configuration Contacts U41840 J Z125 7 76 339 Figure 211 Primary and Secondary Pages ...
Page 402: ...Reports Replication 388 U41840 J Z125 7 76 ...
Page 406: ...Hardware Status 392 U41840 J Z125 7 76 Figure 236 System Board Page ...
Page 432: ...Activity Log Status 418 U41840 J Z125 7 76 ...
Page 442: ...Service Tickets Alerts 428 U41840 J Z125 7 76 ...
Page 462: ...Reboot Shutdown Utilities 448 U41840 J Z125 7 76 ...
Page 470: ...Common Problems and Solutions Troubleshooting 456 U41840 J Z125 7 76 ...
Page 496: ...Additional Specifications for Scale Mode System Specifications S5 626 U41840 J Z125 7 76 ...
Page 634: ...Index 634 U41840 J Z125 7 76 ...