Functions
Item
Main unit
PC/Tablet
Description
Installation
Indoor unit registration
●
—
Indoor unit registration. Max. 400 units. (Set data can be written to and read from USB flash
drive)
Function settings
●
—
Temperature set point limitation, external input, central operation on/off setting
Monitor
Display switching
●
●
Icon display, List display
Display units
●
●
All, Group, Individual (remote control group)
Monitor contents (icon display)
●
●
Group name, operation, operation mode, set temperature, time, errors, timer setting, filter sign
Monitor contents (list display)
●
●
Group name, operation, operation mode, set temperature, airflow, air direction, special opera-
tion, anti-freeze, time, errors, timer setting, filter sign, room temp., human sensor, set temp.
range
Error list
●
●
Group name, remote control group name, address, error code
Special state
●
●
Display during special operation
Control
Control units
●
●
All, Group, Individual (remote control group)
Control contents
●
●
Operation, operation mode, set temperature, airflow, RC prohibition, filter sign reset
Detailed control contents
●
●
Air direction, energy saving, anti-freeze, test run
Individual setting reset of airflow direc-
tion
—
●
Sets the position of indoor unit’s airflow direction louver individually.
Human sensor
—
●
Sets the human sensor on the indoor unit.
Setting temperature limitation of room
●
●
Adjusts the upper and lower limits of temperature for the indoor unit.
Setting
Language setting*
●
●
Design considering multi-language correspondence
Date and time
●
●
Time display switching, year/month/day display switching, system clock setting, summer time,
Internet time adjustment setting
Time zone
●
●
Set the time zone of the area where this unit is used.
Panel cleaning and correction
●
—
Select display area for panel cleaning. User can select black screen on display.
Group
●
●
Stages: Max. 3 stages settable up to 400 groups. (Set data can be written to and read from
USB flash drive.)
Back ground light and beep sound
●
—
Backlighting off time and brightness setting, beep sound operation setting
Password
●
—
Management level: 3 kinds
Schedule timer
●
●
Max. 30 items settable
Temperature range
●
—
Celsius/Fahrenheit switching, cooling, heating, and AUTO each settable
Network
●
●
Function of Email notification for malfunction, or electricity charge apportionment option is used
via LAN
Low noise operation
●
●
“Low noise operation” is set to all outdoor units registered by this controller.
Electricity charge apportionment (Op-
tion)
●
●
Start/stop of ECA, importing/exporting of ECA setting, and exporting ECA data.
Remote language additional registra-
tion
—
●
Additional language can be integrated on remote device by creating language database.
Additional language is displayed on only the remote device and touch panel controller cannot
be added other language.
Auto OFF timer
—
●
Function to stop the operation automatically when a preset time lapses after turning on the op-
eration
Set temperature auto return
—
●
Function to restore the temperature to the original set temperature when a preset time lapses
after changing the set temperature.
Display item setting
—
●
Sets the items to be displayed on the monitor.
Failure notification Email
—
●
Failure notification Email: Sends a notification Email to the preset Email address in the event of
failure.
Remote connection setting
—
●
Create Users: Max. 15 users, type, permissions, unit setting, automatic logout time
Maintenance
Error history
●
●
Recording of max. 10 errors for each touch panel controller and each indoor and outdoor unit
Status history
●
●
Recording of max. 100 operations for each indoor unit
Writable to USB flash drive
Operation history
●
●
Recording of max. 10,000 operations
Writable to USB flash drive
TPC information
●
●
Version history, TPC MAC address, software version, Writing the TPC information
Others
External input/output
●
—
Input: Batch operation/stop, emergency stop, electricity meter
Output: Operation monitoring, error
NOTES:
• *: Product specifications are subject to change without notice.
• When Start/Stop, operation mode setting, room temp. setting, fan speed setting, air flow direction setting, swing setting, economy mode, and anti freeze setting are changed frequently
by using the central controller such as System controller, Touch panel controller, etc. or from Building Management System (BMS) via BACnet gateway or via Network convertor, the
number of operations for each indoor unit must not exceed 7,500 times/year.
If the number of setting change exceeds the above specified number, the rewriting count limit of the non-volatile memory (built into the air conditioner and used for recording settings)
will be exceeded, and may cause breakdown.
2-3. Touch panel controller (UTY-DTGYZ1)
- (05-25) -
2. Control units
CONTROL
SYSTEM
CONTROL
SYSTEM
Summary of Contents for AIRSTAGE J-IIIL
Page 1: ...DESIGN TECHNICAL MANUAL ...
Page 3: ...1 GENERAL INFORMATION 2019 11 01 DV_CH01_J3LU061EF_02 ...
Page 20: ...2 5 Others 01 16 2 Optional parts GENERAL INFORMATION GENERAL INFORMATION ...
Page 21: ...2 MODEL SELECTION 2019 11 01 DV_CH02_J3LU061EF_02 ...
Page 94: ...5 1 Stand alone 02 72 5 Heating capacity table Outdoor unit MODEL SELECTION MODEL SELECTION ...
Page 95: ...3 OUTDOOR UNITS 2019 03 07 DV_CH03_J3LU061EF_01 ...
Page 120: ...11 1 Stand alone 03 24 11 Accessories OUTDOOR UNITS OUTDOOR UNITS ...
Page 121: ...4 INDOOR UNITS 2019 11 01 DV_CH04_J3LU061EF_02 ...
Page 337: ...5 CONTROL SYSTEM 2019 11 01 DV_CH05_VR2E018EF_04 ...
Page 521: ...6 SYSTEM DESIGN 2019 11 01 DV_CH06_J3LU061EF_02 ...
Page 599: ...7 FUNCTION SETTINGS 2019 11 01 DV_CH07_J3LU061EF_02 ...
Page 753: ...8 EXTERNAL INPUT AND OUTPUT 2019 11 01 DV_CH08_J3LU061EF_02 ...
Page 831: ...9 NOTES 2019 11 01 DV_CH09_J3LU061EF_04 ...
Page 850: ...4 2 Wiring connection 09 18 4 About connection between series NOTES NOTES ...
Page 851: ...10 OPTIONAL PARTS 2019 11 01 DV_CH10_VR2E018EF_05 ...