- (05-80) -
SY
ST
EM
DE
SIGN
SY
ST
EM
DE
SIGN
OPTIONAL PARTS INSTALLATION
7.
DRAIN PUMP UNIT
7-1.
DUCT TYPE
7-1-1.
MODEL : UTZ-PX1NBA
SPECIFICATIONS
Unit
Specifications
Height of drain up
mm
Maximum 1000
Power source
-
220-240V, 50/60Hz
Power input (230V, 50/60Hz)
W
12 / 10.8
Current (230V, 50/60Hz)
mA
114 / 92
Dimensions (H x W x D)
mm
176 x 178 x 154
Weight
kg
2.5
Connection pipe diameter
-
VP25 (I.D.25mm, O.D.32mm)
Direction of pipe connection *1
-
360°
Angle of pipe connection *2
-
0° (Horizontal)-90° (Vertical)
Control method
-
Control board of indoor unit
safety device
-
Float switch, Thermal fuse
*1 : Direction of pipe connection
*2 : Angle of pipe connection
APPLICATION INDOOR UNITS
Type
Model name
Duct (Single system)
AR
¾
G36LM, AR
¾
G45LM
Duct (Simultaneous multi system)
AR
¾
G22LM, AR
¾
G24LM
INSTALLATION PLACE
(Unit : mm)
Max.1000
163
176
46
270
787
154
116
166
1177
740
1135
477~550
178
Drain pump unit
Front view
Connected drain pipe (VP25)
(I.D. 25mm; O.D.32mm)
Rear view
470 or more
150 or more
Top view
Air
Note:
Leave the space required to service the unit.
Set a maintenance hole near the drain pump unit.