- (02-84) -
IN
D
O
O
R U
N
IT
(S
IN
G
LE
)
IN
D
O
O
R U
N
IT
(S
IN
G
LE
)
ELECTRIC CHARACTERISTICS
9.
Note : Wiring specification
1. Selected sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
2. Limited wiring length: Limit voltage drop to less than 2%. Increase cable gauge if voltage drop is 2% or more.
3. If the transmission wire is longer than 50m, use the bigger conductor size.
Indoor unit
Power supply
Max. operating
current
(Indoor unit)
(A)
Wiring specification
(Indoor unit to outdoor unit)
Type
Model name
Voltage
(V)
Frequency
(Hz)
Connection cable
(mm
2
)
Limited wiring length
(m)
CASSETTE
AU
G36LR
230 ~
50
1.1
1.5 (Min.)
75
AU
G45LR
1.2
AU
G54LR
1.2
DUCT
AR
G36LM
230 ~
50
2.0
1.5 (Min.)
75
AR
G45LM
2.1
HIGH
STATIC
PRESSURE
DUCT
AR
G45LH
230 ~
50
4.0
1.5 (Min.)
75
AR
G54LH
CEILING
AB
G36LR
230 ~
50
0.7
1.5 (Min.)
75
AB
G45LR
0.8
AB
G54LR
1.0