GROUP CONTROL
Max 16 indoor units are simultaneously controlled with a wired remote controller.
Refrigerant
pipe
Refrigerant pipe
Wired R.C.
OR
Max 16 indoor units
Indoor unit 0
Indoor unit 1
(Primary)
Indoor unit 2
(Secondary)
Indoor unit 15
Set the remote control address using DIP switch or Rotary switch (High static pressure duct type only) on
indoor unit circuit board.
Wireless R.C.
* In simultaneous control,
the timer and 10°C HEAT function by using
the wireless remote controller
cannot be used.
Bus wire
Transmission/
Power supply cable
Power supply cable
Remote controller cable
* In the group connection of different models, the functions which can be set by using the wired remote controller are
limited.