![Fujitsu AB*G18LVTB Series Design & Technical Manual Download Page 210](http://html.mh-extra.com/html/fujitsu/ab-g18lvtb-series/ab-g18lvtb-series_design-and-technical-manual_118007210.webp)
- (04-01) -
O
U
TD
O
O
R
UN
IT
O
U
TD
O
O
R
UN
IT
SPECIFICATIONS
1.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB / 24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB / 6 °CWB.
Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
The protective function might work when using it outside the operation range.
Type
INVERTER HEATPUMP
Model name
AO
Û
G36LATT
AO
Û
G45LATT
AO
Û
G54LATT
Power source
3N ~ 400V 50Hz
Available voltage range
3N ~ 342V - 457V 50Hz
Starting current
A
4.4
6.1
6.9
Fan
Airflow
rate
Cooling
m
3
/h
6200
6750
6900
Heating
6200
6200
6900
Type × Q'ty
Propeller × 2
Motor output
W
104
Sound pressure level
Cooling
dB (A)
51
54
55
Heating
53
54
56
Sound power level
Cooling
dB (A)
67
-
-
Heating
69
-
-
Heat exchanger type
Dimensions (H × W × D)
mm
1260 × 900 × 36.4
Fin pitch
1.30
Rows x Stages
2 × 60
Pipe type
Copper
Fin
Type (Material)
Corrugate (Aluminium)
Surface treatment
Corrosion resistance (Blue fin)
Compressor
Type × Q'ty
Twin Rotary × 1
Motor output
W
3750
Refrigerant
Type (Global Warming Potential)
R410A (1975)
Charge
g
3450
Refrigerant oil
Type
POE
Enclosure
Material
Steel sheet
Colour
BEIGE
(Approximate colour of MUNSELL 10YR 7.5 / 1.0)
Dimensions
(H × W × D)
Net
mm
1290 × 900 × 330
Gross
1430 × 1050 × 445
Weight
Net
kg
104
Gross
113
Connection pipe
Size
(Standard)
Liquid
mm
Ø 9.52 (Ø 3/8 in.)
Gas
Ø 15.88 (Ø 5/8 in.)
Method
Flare
Pre-charge length
m
30
Max. length
75
Max. height difference
30
Operation range
Cooling
°C
-15 to 46
Heating
-15 to 24