H3-192
MAINTENANCE 3. TROUBLESHOOTING
006-252-05
06.30.01 FM3040
FM-DP L
Service Manual
H3-192
Power OFF
FP3F0E97.EPS
Power ON
Adjust SA6 attaching position.
Or replace SA6.
Refer to "4. Inspecting, Replacing,
Adjusting Parts".
Check error generation state.
Check error details at
[Error Log Data] of M-Utility.
Y
Is SA1/SB1 ON?
Check at [Sensor Monitoring] of
[Check Mechanism] of M-Utility.
Release tray lock.
Insert tray shutter while pulling out tray.
Insert tray shutter and pull out tray.
Remove film, and push tray back in to
its original position.
Remove covers.
N
N
Are +5Vcc/+24VB voltages output
normally?
Refer to "3.5 Troubleshooting
Reference".
Supplementary Note:
Check that suction cup arm is at upper dead-point.
Y
Is SA6 ON?
Check at [Sensor Monitoring] of
[Check Mechanism] of M-Utility.
N
Recover NFB.
For direct-bonded fuse,
replace the DRV11A board.
Y
Are NFB of power supply unit and
NFB6 of DRV11A board normal?
Refer to "3.5 Troubleshooting
Reference".
N
Replace fuse.
Y
Is fuse of power supply unit normal?
Refer to "3.5 Troubleshooting
Reference".
N
Y
Are cables normal?
Check connector connection, cable
conduction, and connector pins.
Repair or replace.
N
Replace power supply unit.
Y
1
2