H3-59
006-252-02
10.22.99 FM2569
FM-DP L
Service Manual
H3-59
MAINTENANCE 3. TROUBLESHOOTING
Error code
Error name
Significance
Probable cause and remedy
Detailed
information format
12D7
Sorter unit detection
invalid command
The sorter unit received a message
command at the unacceptable timing.
As a result, the desired command cannot
be executed. Refer to the detailed
information format.
After initializing the sorter unit again, execute the sorter
discharge conveyance or utility command.
2-3-C
12D8
Sorter unit detection
storage cancellation
Storage in the sorter unit has been
forcibly canceled.
As a result, the film may be remaining in
the sorter unit.
This is not a problem because sorter conveyance was
intentionally stopped due to film jamming in the heat
development unit.
2-3-E1
12E0
Upper cover open error
The upper cover is open.
Close the upper cover. Check SJ1.
None
12E1
Front cover open error
The front cover is open.
Close the front cover and check SJ2 and SJ3.
None
12E2
Sorter entrance film
JAM
Attempted to convey film into the sorter
unit, but the sorter unit sensor 1 (ST1)
did not turn ON.
2-3-A
12E3
Sorter simultaneously
conveyed films
exceeded error
Because the number of films which the
sorter unit can convey simultaneously
has been exceeded, switched the film
discharge location to the top of the main
body.
Possibility of film jamming in the sorter unit is high.
Check for sorter unit problems before and after this log.
2-3-E1
12E4
Sorter conveyance
ready error
As sorter conveyance was attempted
even though conveyance has been
disabled due to malfunction of the sorter
unit just before conveyance, switched
the film discharge location to the top of
the main body.
Since this error is due to other sorter problems, check for sorter
unit problems before and after this error log.
2-3-E1
12E5
Sorter conveyance
canceled
Attempted to convey film to the sorter
unit, but due to malfunction of the sorter
unit just before conveyance, sorter
conveyance was canceled.
Only when discharge to the top of main
body was late.
Since this error is due to other sorter problems, check for sorter
unit problems before and after this error log.
2-3-E1
12E6
Sorter storage
command acceptance
failure
Request storage in the sorter sorter
during conveyance, but the unit did not
accept the storage command.
Since this error is most likely due to other sorter problems,
check for sorter unit problems before and after this error log.
•SIO transmission error (12C2)
•SIO reception error (12C3)
2-3-E1
1. Check if the operations of the changeover guide (SOLG1)
of the heat development unit are abnormal.
2. Check that the sorter unit is connected correctly.
3. Check the ST1 of the sorter unit and motor.
4. Replace the parts/boards of the sorter unit.