H3-89.15
006-252-05
06.30.01 FM3040
FM-DP L
Service Manual
H3-89.15
MAINTENANCE 3. TROUBLESHOOTING
Error Codes Detected by Remote Panel
Error code
Error name
Significance
Probable cause and remedy
Detailed
information format
0001
Exchange error with
main body during start
up
Main body and remote panel could not
exchange at start up.
None
0101
Command time-out error
with main body
Setting of timer value of storage time-out
was incorrect.
Faulty input board (DPI/DVI)
Faulty CPU board
Faulty remote panel
Faulty software
Set the correct storage time-out timer value.
Replace the corresponding input board.
Replace the CPU board.
Replace the remote panel.
None
If while installing the main body software, stop the alarm and
continue.
Do not turn off the power supply. If performing operations other
than installation, the remote panel, cable connecting the main
body, input board, and CPU may be faulty.
1. Replace the cable.
2. Replace in the order of input board, CPU board, and remote
panel.