7-6
7.3 Measurement of Electrical Amounts in Main Circuit
Because the voltage and current of the power supply (input, primary circuit) of the main circuit of the
inverter and those of the motor (output, secondary circuit) include harmonic components, the
readings may vary with the type of the meter. Use meters indicated in Table 7.3 when measuring with
meters for commercial frequencies.
The power factor cannot be measured by a commercially available power-factor meter that
measures the phase difference between the voltage and current. To obtain the power factor,
measure the power, voltage and current on each of the input and output sides and calculate in the
following formula.
Three-phase input
Single-phase input
%
100
×
(A)
t
(V)×Curren
×Voltage
3
(W)
power
Electric
=
factor
Power
%
100
×
(A)
t
(V)×Curren
Voltage
(W)
power
Electric
=
factor
Power
Table 7.3 Meters for Measurement of Main Circuit
Item
Input (primary) side
Output (secondary) side
DC link bus
voltage
(P (+)-N (-))
W
avefor
m
Voltage
Current
Voltage
Current
Name of
meter
Ammeter
A
R
, A
S
, A
T
Voltmeter
V
R
, V
S
, V
T
Wattmeter
W
R
, W
T
Ammeter
A
U
, A
V
, A
W
Voltmeter
V
U
, V
V
, V
W
Wattmeter
W
U
, W
W
DC voltmeter
V
T
ype of
meter
Moving iron
type
Rectifier or
moving iron
type
Digital AC
power meter
Digital AC
power meter
Digital AC
power meter
Digital AC
power meter
Moving coil type
Symbol
of meter
It is not recommended that meters other than a digital AC power meter be used for
measuring the output voltage or output current since they may cause larger measurement
errors or, in the worst case, they may be damaged.
Figure 7.1 Connection of Meters
Summary of Contents for Frenic Mini FRN001C1E-2U
Page 85: ...5 4 ...
Page 88: ...5 7 ...
Page 89: ...5 8 C codes Control Functions of Frequency ...
Page 92: ...5 11 J codes Application Functions y codes Link Functions ...
Page 167: ...8 6 8 3 Common Specifications ...
Page 168: ...8 7 ...
Page 171: ...8 10 8 5 External Dimensions 8 5 1 Standard models ...
Page 172: ...8 11 ...
Page 173: ...8 12 8 5 2 Models available on order EMC filter built in type ...
Page 174: ...8 13 ...
Page 192: ...MEMO ...
Page 193: ...MEMO ...
Page 194: ...MEMO ...
Page 196: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 06 F07 F07 00CM ...