![Fuji Electric Frenic Mini FRN001C1E-2U Instruction Manual Download Page 41](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-frn001c1e-2u/frenic-mini-frn001c1e-2u_instruction-manual_2341842041.webp)
2-19
Table 2.7 Continued
Classifi-
cation
Symbol Name
Functions
[FMA] Analog
monitor
The monitor signal for analog DC voltage (0 to +10 VDC) is output. The
signal functions can be selected from the following with function code F31.
- Output frequency (before slip compensation)
- Output frequency (after slip compensation)
- Output
current
- Output
voltage
- Input power
- PID feedback amount
- DC link bus voltage
- Calibration
*Input impedance of external device: Min. 5 k
:
Analog output
[11] Analog
common
Common terminal for analog input and output signals
This terminal is electrically isolated from terminals [CM] and [Y1E].
(1) Various signals such as inverter running, speed/freq. arrival and over-
load early warning can be assigned to the terminal [Y1] by setting
function code E20. Refer to Chapter 5, Section 5.2 "Overview of Func-
tion Codes" for details.
(2) Switches the logic value (1/0) for ON/OFF of the terminals between [Y1]
and [Y1E]. If the logic value for ON between [Y1] and [Y1E] is 1 in the
normal logic system, for example, OFF is 1 in the negative logic system
and vice versa.
Digital input circuit specification
Figure 2.17 shows examples of connection between the control circuit and a
PLC.
[Y1] Transistor
output
- Check the polarity of the external power inputs.
- When connecting a control relay, first connect a surge-absorbing
diode across the coil of the relay.
[PLC] Transistor
output
power
Power source of +24 VDC to be fed to the transistor output circuit load (50mA
at maximum).
To enable the source, it is necessary to short-circuit between terminals [Y1E]
and [CM].
Can also be used as a 24 VDC power source.
This terminal serves also as a digital input one.
T
ransistor
outp
ut
[Y1E] Transistor
output
common
Common terminal for transistor output signal
This terminal is electrically Isolated from terminals [CM] and [11].
Item Max.
ON level
2 V
Operation
voltage
OFF level
27 V
Maximum load current
at ON
50 mA
Leakage current at OFF
0.1 mA
Summary of Contents for Frenic Mini FRN001C1E-2U
Page 85: ...5 4 ...
Page 88: ...5 7 ...
Page 89: ...5 8 C codes Control Functions of Frequency ...
Page 92: ...5 11 J codes Application Functions y codes Link Functions ...
Page 167: ...8 6 8 3 Common Specifications ...
Page 168: ...8 7 ...
Page 171: ...8 10 8 5 External Dimensions 8 5 1 Standard models ...
Page 172: ...8 11 ...
Page 173: ...8 12 8 5 2 Models available on order EMC filter built in type ...
Page 174: ...8 13 ...
Page 192: ...MEMO ...
Page 193: ...MEMO ...
Page 194: ...MEMO ...
Page 196: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 06 F07 F07 00CM ...