5-29
For three-phase 230 V and single-phase 230 V/115 V class series of
inverters
Outputting the output current in an analog format (FMA) (F31 = 2)
The analog output terminal [FMA] outputs 10 V, that is, 200% of the ref-
erence current
I
ref
(A), supposing the output gain selected with F30 as
100%. Therefore, to adjust the output voltage, you need to set the output
gain at terminal [FMA] (F30) based on the conversion result obtained by
the following expression:
z
Conversion formula for calculating the output gain which is required for
outputting the voltage V (V) via terminal [FMA] when current
I
(A) flows
across the inverter
100
(V)
10
(V)
V
(A)
(A)
2
=
gain
Output
ref
u
u
u
I
I
I
ref
(A): Reference current (A)
The reference current is given in the table for F20 to F22 on page
5-26.
According to the conversion result, the output voltage to terminal [FMA]
can be calculated as shown below.
(V)
10
100
(F30)
gain
Output
(A)
2
(A)
=
(V)
voltage
output
Analog
ref
u
u
u
I
I
(Example) Outputting analog voltage 8V for 0.75 kW standard motors
when the inverter output current is 4.2A
190.4
100
(V)
10
(V)
8
(A)
4.2
(A)
5.0
2
=
gain
Output
u
u
u
7.98
(V)
10
100
190
(A)
5.0
2
(A)
4.2
=
(V)
voltage
output
Analog
u
u
u
Reference table
If you want to output analog 10 V at 200% of the rated current of any of the
single-phase 115 V class series of inverters, set the output gain at terminal
[FMA] (F30) as listed below.
Applicable motor rating (HP)
1/8
1/4
1/2
1
Output gain to be set to F30 (%)
114
107
120
119
F43, F44
Current Limiter (Mode selection and Level)
F43 enables or disables the current limiter. If it is enabled, the inverter controls the
output frequency so that the output current of the inverter does not exceed the level
set by F44. This way it prevents the motor from stalling and limits the output current
below the set level.
With F43, you may select whether the current limiter works during constant speed
operation only (F43 = 1) or during both acceleration and constant speed operation
(F43 = 2). Set F43 to 1, for example, to drive the motor at maximum performance in
the acceleration zone and to limit the drive current in the constant speed zone.
Summary of Contents for Frenic Mini FRN001C1E-2U
Page 85: ...5 4 ...
Page 88: ...5 7 ...
Page 89: ...5 8 C codes Control Functions of Frequency ...
Page 92: ...5 11 J codes Application Functions y codes Link Functions ...
Page 167: ...8 6 8 3 Common Specifications ...
Page 168: ...8 7 ...
Page 171: ...8 10 8 5 External Dimensions 8 5 1 Standard models ...
Page 172: ...8 11 ...
Page 173: ...8 12 8 5 2 Models available on order EMC filter built in type ...
Page 174: ...8 13 ...
Page 192: ...MEMO ...
Page 193: ...MEMO ...
Page 194: ...MEMO ...
Page 196: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 06 F07 F07 00CM ...